PVAG Chapter 5

CHAPTER 5: GENERAL PASSENGER VESSEL ELEMENTS

V501 General

V501.1 Scope.  The provisions of Chapter 5 shall apply where required by Chapter 2 or where referenced by a requirement in this document.

V502 Stairways

V502.1 General.  Stairs shall comply with V502.

V502.2 Treads and Risers.  All steps on a flight of stairs shall have uniform riser heights and uniform tread depths.  Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum.  Treads shall be 11 inches (280 mm) deep minimum.

V502.3 Open Risers.  Open risers are not permitted.

V502.4 Tread Surface.  Stair treads shall comply with V302.  Changes in level are not permitted.

EXCEPTION:  Treads shall be permitted to have a slope not steeper than 1:48.

V502.5 Nosings.  The radius of curvature at the leading edge of the tread shall be ½ inch (13 mm) maximum.  Nosings that project beyond risers shall have the underside of the leading edge curved or beveled.  Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical.  The permitted projection of the nosing shall extend 1½ inches (38 mm) maximum over the tread below.

V502.6 Handrails.  Stairs shall have handrails complying with V503.

V502.7 Wet Conditions.  Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water.

V503 Handrails

V503.1 General.  Handrails provided along walking surfaces complying with V403, required at ramps complying with V405, provided at elevators complying with V407 or V408 and platform lifts complying with V409, required at gangways complying with V413 and required at stairs complying with V502, shall comply with V503.

V503.2 Where Required.  Handrails shall be provided on both sides of stairs, gangways, and ramps.

EXCEPTION:  In assembly areas, handrails shall not be required on both sides of aisle ramps where a handrail is provided at either side or within the aisle width.

V503.3 Continuity.  Handrails shall be continuous within the full length of each stair flight, gangway run, or ramp run.  Inside handrails on switchback or dogleg stairs and ramps shall be continuous between flights or runs.

EXCEPTION:  In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating.

V503.4 Height.  Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, gangway surfaces, and ramp surfaces.  Handrails shall be at a consistent height above walking surfaces, stair nosings, gangway surfaces, and ramp surfaces.

EXCEPTION:  This section shall not apply to handrails along walking surfaces with slopes not steeper than 1:20 that are required by the administrative authority to be located more than 38 inches (965 mm) above deck surfaces.

V503.5 Clearance.  Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum.

V503.6 Gripping Surface.  Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides.  The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length.  Where provided, horizontal projections shall occur 1½ inches (38 mm) minimum below the bottom of the handrail gripping surface.

EXCEPTIONS:  1.  Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length where they are integral to crash rails or bumper guards.

2.  The distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8 inch (3.2 mm) for each ½ inch (13 mm) of additional handrail perimeter dimension that exceeds 4 inches (100 mm).

V503.7 Cross Section.  Handrail gripping surfaces shall have a cross section complying with V503.7.1 or V503.7.2.

V503.7.1 Circular Cross Section.  Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.

V503.7.2 Non-Circular Cross Sections.  Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section dimension of 2¼ inches (57 mm) maximum.

V503.8 Surfaces.  Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges.

V503.9 Fittings.  Handrails shall not rotate within their fittings.

V503.10 Handrail Extensions.  Handrail gripping surfaces shall extend beyond and in the same direction of stair flights, gangway runs and ramp runs in accordance with V503.10.

EXCEPTIONS:  1.  Extensions shall not be required for continuous handrails at the inside turn of switchback or dogleg stairs and ramps.

2.  In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers within aisles.

3.  In alterations, full extensions of handrails shall not be required where such extensions would be hazardous due to plan configuration.

V503.10.1 Top and Bottom Extension at Ramps.  Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs.  Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run.

V503.10.2 Top Extension at Stairs.  At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing.  Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight.

V503.10.3 Bottom Extension at Stairs.  At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing.  Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight.